Keeping your wiring organized is a never-ending struggle. Make sure to
make it as easy as possible.
fire safety considerations
types of cable:
riser
CM, CMG, CMxhttp://www.l-com.com/multimedia/video_clips/video.aspx?ID=13100 Video: Flammability Tests
plenum
low-smoke zero halogen
Under Floor Organization
Place your major power lines in properly grounded metal conduit.
Put all under-floor fiber connections in plenum-certified
conduit,
such as the orange crinkle tube.
If using electrical whips underneath floors, make sure the socket
boxes are physically restrained in place and marked with the
location on both ends.
Run all conduits and wires square to the floor panels to allow
for easier under-floor organization.
When placing electrical power whips underneath the floor, take
the time to make sure they are cut very close to length, as extra
loops of this cable can take up a lot of space under the floor.
Physically separate power from network cabling as much as possible. You may have only power conduits and cables under the raised floor, and network cabling in overhead cable trays, or vice-versa.
Rack to Rack Connections
Consider whether you want to use network switches and hubs in
each rack and connect those to a central location, or use patch
panels that go from rack to rack.
Use patch panels and other techniques to minimize how often you
have to go into the floor. You should not need to lift floor
panels to install a new computer.
Keyboard Video Mouse Switches
Consider using your KVM connections sparingly, using only one
or two per rack and moving them when necessary for maintenance.
Buy a high-quality KVM, as quality counts, and go with an
on-screen menu that allows you to label the computers.
Make sure your KVM allows for keyboard switching.
Compare against serial terminal servers if you have Unix boxes.
Use true KVM cables. Cables that you zip-tie
together are harder to remove later. Also, the video
connection that uses screws is shorter than the PS/2 connections, to reduce cable pull out.
Cable Management
Many products for rack cable management.
Velcro zipties are reusable.
Use Ethernet cables of many color and lengths.
Consider color coding by length. Use only booted
cables as they won't get caught up when being moved around.
Consider putting a unique serial number on both ends of every single cable going
into your data center.
Use the shortest power cables possible. Put serial numbers
on the power cables and consider using black and beige colored
cables to show side-to-side redundancy.
Pre-plan location of power outlets on rack systems.
Planning for Expansion
Plan for extra analog phone jacks during construction, as they
are often used for modems on equipment. Consider making them
56K leased-line capable.