Skip to main content

  | मौसम…

411 समाचार
Public archive edition · Attributed source reporting with original dates · AI drafts are excluded

411 REFERENCE · Wikibooks

360 Assembly/360 Instructions/S

Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.

__TOC__ S - Add - Opcode 5B Format S 2,N2 S 11,106(0,10) The specific syntax is S target register, offset (index register, base register) Where the offset, index register and base register values will be determined automatically by the assembler if the USING pseudo-instruction has been used, and the target address label used is within 4096 bytes of the value of some base register. RX Instruction (4 bytes)Byte 1Byte 2Bytes 3 and 4target registerSource Address(8 bits)Opcode5B(4 bits) 0..F(4 bits)indexregister0..F(4 bits)baseregister0..F(12 bits)offset0..FFF The first argument is a target register which value is affected by the instruction. The second argument is the source value location. The mask, base_register and index_register values are 0 to 15. The offset value is 0 to 4095. Availability The S instruction is available on all models of the 360, 370 and z/System. Operation The S instruction reads a 32-bit integer value from the memory address specified by the argument and subtracts it from the value of the register specified by the first argument. The register specified by the first argument holds the operation result after the instruction is executed. The Condition Code field in the Program Status Word is changed according to the resulting value. The source argument address shall be aligned to the word boundary (i.e. 4 bytes). Condition Codes If signed integer overflow occurs, i.e. difference is not between -2**31 and 2**31-1, CC is set to 3. Otherwise, CC is set to 0, 1 or 2, if difference is equal to zero, below zero or above zero accordingly. Exceptions and Faults If signed integer overflow is detected and the bit 36 in PSW is set, an operation exception occurs. The target address must be within the range of valid memory or an operation exception occurs. The storage key for the target address must be the same as the current process or a memory protect violate exception occurs. Related instructions To subtract by value from register, see SR. To subtract by half-word value from memory, see SH. To subtract by value and set condition codes according to unsigned arithmetic, or subtract not the most significant part of a multi-word integer value, see SL or SLR. To subtract floating-point values, see SE, SER, SD or SDR. To add integer value, see A, AR, AH, AL or ALR. To check condition code, see BC or BCR. RSCH SAC 5A A 5C M