Skip to main content

  | मौसम…

411 समाचार
Public archive edition · Attributed source reporting with original dates · AI drafts are excluded

411 REFERENCE · Wikibooks

OPT Design

Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.

thumb|upright 1.5|Output Transformer Design Basics Tube Output Transformer Design The goal of this book is to show the world how an output transformer or OPT may be designed and what to think of. Theory The fundamental consideration is that the core must not go into saturation at any voltage or frequency. That means that the core must widthstand: Due to DC almost always being present (especially true in single-end designs) we must also consider the magnetic intensity H: where lm is the mean magnetic length around the core. It can furthermore be shown that the primary inductance need emerges from the fact that where RL is the reflected load resistance and rp is the plate resistance of the tube(s). This yields the equation where ZL is the loudspeaker nominal impedance and n the turn-ratio of the transformer. It can furthermore be shown that maximum output power occurs when each tube is loaded by Knowing this the minimum inductance L may be calculated. The small signal model do however also put restrictions on HF parameters. If the OPT is carefully wound (in sectors and not bifilarysimilar to bifilarly October 2022 as well as at least one layer of transformer tape inbetween each layer) the main HF problem will be a so called leakage inductance. The equation for calculating this is: or This parameter is however very hard to control. But experience has showed that one important thing is that the secondary winding must cover the whole (or both) primaries. Another idea is that the winding ends must not be folded. This last part might mainly eliminate HF resonances. The inductance of a toroidal transformer can be expressed as: where where lg is the length of the air-gap and lm is the mean magnetic length. If lg is zero, this simplifies to where is the relative permeability of the iron and is the permeability of vacuum. A Practical Example It can be shown that a single-pole low-pass filter roll-off yields an only -0,5dB impact on the frequency three times lower than fh. This means that if we want -0,5dB at highest audible frequency (20kHz) we would need a fh of 60kHz. Because this means a leakage inductance of less than if we want to use KT66 tubes in push-pull (PP) where rp=2rp(KT66)=2500 Ohm. Observe that RL in PP-designs is 4 times the load on each tube. Optimum plat-to-plate load is thus 10k Ohms in our case. The same thing is valid for single-pole high-pass filters, thus fl for -0.5dB@10Hz is 3,3Hz. The inductance therefor needs to be greater than If we want to use the suggested core dimensions we get and Because P1+P2 needs to widthstand 230V@15Hz and a common maximum flux density for transformer irons is around the number of turns can now be calculated using the first equation. This gives Putting this into the equation for the primary inductance we get Because we want to use the OPT in Class A push-pull configuration we need not take too much consideration of the DC that will flow due to tube aging and loudspeaker impedance variation with frequency. But it is recommended that the OPT should widthstand at least 10mADC thru both primaries. In SE-configuration a so called air-gap would be needed but this cannot (easily) be realised in toroidal transformers which makes us dependent on the width of the BH-loop of the used iron. The magnetic intensity for a DC current of 10mA is for our transformer: and here we want to have at least L/3=30H left. Equation Derivation In this paragraph the derivation of the above used equations will be explained. Standard OPT Usage thumb|Standard OPT Usage This picture shows how an OPT is used in push-pull (PP) configuration. The below theory is however also valid for single-end (SE) configurations. OPT Small Signal Model thumb|OPT Small Signal Model This picture shows the small signal model of the OPT. Fig.1 shows the trivial OPT connection i.e driven by the generator G thru two plate resistances rp (because of PP). Fig.2 shows what happens at low frequencies where the OPT works as an ordinary transformer. Reflected impedance is therefor where n is the turn ratio of the OPT and ZL is the loudspeaker impedence. Fig.3 shows what happens at high frequencies where the leakage inductance LL is dominant over the interlayer capacitance (due to special winding techniques described earlier). The above expression still holds though. Transformer Basics Consider an ideal transformer without iron or copper losses. The output power will then be equal to the input power. If you transform a high voltage to a low voltage you will be then able to extract a higher current at the secondary than you are putting in on the primary. So if then and if it follows that and finally or Small Signal Model Evaluation While using Norton and Thevenin circuit theory in Fig.2 we get: In Fig.3 we may however just realize the fact that because this is where the reactance of LL becomes dominant. Standard Filter Characteristics Imagine a single-pole High-Pass filter. Then you might have a capacitor in series with a resistor to ground. The Laplace transfer function then yields or simplified Putting we get Putting s=jw we get and the amplitude of the transfer function gets or where f is the frequency. Putting we get Field Magnetics In this paragraph we will show the world the electromagnetic fundamentals. Maxwell's Equations The normal form of Maxwell's Equations is The first equation, Gauss's Law, describes how electrical fields are caused by electrical charges. The second equation states that there are no "magnetic charges", or so called magnetic monopoles. The third equation, Faraday's Law, describes how electrical fields are created due to magnetic field variations. The fourth equation, Ampere's Law (with Maxwell's correction), describes how magnetic fields are created from electrical field variations. A List of the Used Quanteties E : Electric Field Intensity [V/m] D : Electric Flux Density [As/m^2] H : Magnetic Field Intensity [A/m] B : Magnetic Flux Density [Vs/m^2] Jf : Free Current Density [A/m^2] Integral Form Boundary Limits Going from medium 1 to medium 2 Maxwell's Equations gives where is the surface charge density och Kf the free surface current intensity between the mediums. Faraday's Law Consider Faraday's Law where we have from Maxwell's Equations: If we define: =emf induced in the curvature C [Volt] and =magnetic flux thru the surface S [Vs or Weber] then we get: [Volt] If we use several turns N of wire we get [Volt] And if the magnetic flux flows thru an iron where the magnetic flux will stay in the iron only, yielding a secondary voltage proportional to the turn ratio n. Magnetic Flux Density in an Iron Core From Faraday's Law we have And due to no variations in the surface S, we have Using the equation we then get A sinusoidal magnetic flux density yields and thus which maximum occurs when Thus or where A has been substituted for S And if the voltage is sinusoidal we get Magnetic Field Intensity in an Iron Core From Maxwell's Equations we get because we are considering DC only and a homogenous surface. So if we are using a toroid, then and if then Effective Permeability due to Air-Gap Applying Ampere's law we once again get Here we also have But in the core we will have and in the air-gap This gives This may be rewritten as or where which gives or Toroidal Core Inductance Consider cylindrical coordinates. Then we get Since the path encircles a total current NI, we have Knowing the relationship it is easy to relate to the earlier equations, thus and which equals Using that the flux linkage is and that the small signal inductance is independent of the current, we get C-Core Inductance This is not so easy to calculate but we can do some approximations if the mean magnetic length could be defined by where c is the shortest leg (at the center of the iron) and d the longest dito leg. Approximating this to a circular toroidal shape, we get Adding half of the thickness of the iron to this we get b, subtracting half of the thickness we get a. Then we might reuse This should be quite valid due to the magnetic flux staying in the iron because of Optimizing Tube Amp Load thumb|Maximum Available Power for Triodes If we consider and realize that output power may be written and derivated by Ia this gives with maxima for thus From the image we can see that where Ua disappears so that or thus A more simple way to prove this is by inspection of image: This finally proves that optimum load for a triode is double it's internal resistance. It should however be pointed out that plate voltage should be the limiting factor, for higher voltages where plate dissipation comes into the picture, Ra must be higher. It is also interesting to note that the efficiency is only 25% in this case, we can prove this by putting: with thus O Electronics 25%