Chemical Sciences: A Manual for CSIR-UGC National Eligibility Test for Lectureship and JRF/Magnetic resonance force microscopy

Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.

Magnetic resonance force microscopy (MRFM) is an imaging technique that acquires magnetic resonance images (MRI) at nanometer scales, and possibly at atomic scales in the future. MRFM is potentially able to observe protein structures which cannot be seen using X-ray crystallography and protein nuclear magnetic resonance spectroscopy. Detection of the magnetic spin of a single electron has been demonstrated using this technique. The sensitivity of a current MRFM microscope is 10 billion times better than a medical MRI used in hospitals. Basic principle The MRFM concept combines the ideas of magnetic resonance imaging (MRI) and atomic force microscopy (AFM). Conventional MRI employs an inductive coil as an antenna to sense resonant nuclear or electronic spins in a magnetic field gradient. MRFM uses a cantilever tipped with a ferromagnetic (iron cobalt) particle to directly detect a modulated spin gradient force between sample spins and the tip. As the ferromagnetic tip moves close to the sample, the atoms’ nuclear spins become attracted to it and generate a small force on the cantilever. The spins are then repeatedly flipped, causing the cantilever to gently sway back and forth in a synchronous motion. That displacement is measured with an interferometer (laser beam) to create a series of 2-D images of the sample, which are combined to generate a 3-D image. The interferometer measures resonant frequency of the cantilever. Smaller ferromagnetic particles and softer cantilevers increase the signal to noise ratio. Unlike the inductive coil approach, MRFM sensitivity scales favorably as device and sample dimensions are reduced. Because the signal to noise ratio is inversely proportional to the sample size, Brownian motion is the primary source of noise at the scale in which MRFM is useful. Accordingly, MRFM devices are cryogenically cooled. MRFM was specifically devised to determine the structure of proteins in situ. Milestones The basic principles of MRFM imaging and the theoretical possibility of this technology were first described in 1991J. A. Sidles Noninductive detection of single-proton magnetic resonance Applied Physics Letters 58 2854–6 1991 0.1063/1.104757. The first MRFM image was obtained in 1993 at the IBM Almaden Research Center with 1-μm vertical resolution and 5-μm lateral resolution using a bulk sample of the paramagnetic substance diphenyipicrylhydrazilO. Zuger and D. Rugar First images from a magnetic resonance force microscope Applied Physics Letters 63 2496–8 1993 10.1063/1.110460. The spatial resolution reached nanometer-scale in 2003.S. Chao, W. Dougherty, J. Garbini, J. Sidles Nanometer-scale magnetic resonance imaging Review of Scientific Instruments 75 1175–81 2003 10.1063/1.1666983 Detection of the magnetic spin of a single electron was achieved in 2004D. Rugar, R. Budakian, H. Mamin, B. Chui Single spin detection by magnetic resonance force microscopy Nature 430 329–32 2004 10.1038/nature02658 15254532 6997. In 2009 researchers at IBM and Stanford announced that they had achieved resolution of better than 10 nanometers, imaging tobacco mosaic virus particles on a nanometer-thick layer of adsorbed hydrocarbons.C. L. Degen, M. Poggio, H. J. Mamin, C. T. Rettner, and D. Rugar Nanoscale magnetic resonance imaging PNAS 10.1073/pnas.0812068106 2009 106 1313 19139397 5 2628306 External links University of Washington Quantum System Engineering and MRFM Home Page, http://courses.washington.edu/goodall/MRFM/. Magnetic-Resonance Force Microscopy, http://www.medgadget.com/archives/2005/04/magneticresonan.html. Degen CL, Poggio M, Mamin HJ, Rettner CT, Rugar D Nanoscale magnetic resonance imaging PNAS 12 January 2009 19139397 10.1073/pnas.0812068106 http://www.physorg.com/news151073713.html 106 5 1313–7 2628306 We have combined ultrasensitive magnetic resonance force microscopy (MRFM) with 3D image reconstruction to achieve magnetic resonance imaging (MRI) with resolution <10 nm. BBC NEWS - Science & Environment - IBM team boosts MRI resolution http://news.bbc.co.uk/1/hi/sci/tech/7826901.stm 2009-01-14 13 January 2009 References 2