411 REFERENCE · Wikibooks
HydroGeoSphere/Surface Flow (Properties)
Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.
Default surface flow values
Unless you modify the default values, all zones (and elements) in the surface flow domain will be assigned the default properties listed in Table 5.18:
+Table 5.18Table 5.18: Default Properties for Surface Flow Parameter Value Unit Name Surface flow defaults - X friction factor 0.0548 - Y friction factor 0.0548 - Rill storage height 0.0 m Obstruction storage height 0.0 m Node coupling scheme shared - Coupling length 1 × 10−4 m
For each instruction we will again indicate its scope (i.e. .grok, .oprops). Recall that if an instruction is used in the prefix.grok file, it will affect the current set of chosen zones, while in a properties (e.g. .oprops) file, it will only affect the named material of which it is a part.
X friction
Scope: .grok .oprops
val x friction factor, in Equation 2.35.
• • •
Y friction
Scope: .grok .oprops
val y friction factor, in Equation 2.36.
• • •
Rill storage height
Scope: .grok .oprops
val Rill storage height [L], in Section 2.2.2.2.
• • •
Obstruction storage height
Scope: .grok .oprops
val Obstruction storage height [L], in Section 2.2.2.2.
• • •
Coupling length
Scope: .grok .oprops
val Coupling length [L], in Equation 2.71.
• • •