411 REFERENCE · Wikibooks
FHSST Physics/Magnets and Electromagnetism/Alternating Current
Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.
Alternating Current
Most students of electromagnetism begin their study with what is known as direct current (DC).
In a DC system, the current (the flow of charged particles) is in a constant direction.
In a DC system, the voltage across each part has a constant polarity.
DC is the kind of electric power made by a battery (with
definite positive and negative terminals), or the kind of charge generated by rubbing certain types of materials against each other.
As useful and as easy to understand as DC is, it is not the only "kind" of electric power in use. Certain sources of electric power (most
notably, rotary electro-mechanical generators) naturally produce voltages alternating in polarity, reversing positive and negative over
time. Either as a voltage switching polarity or as a current switching direction back and forth, this "kind" of electric power is
known as Alternating Current (AC):
Fhsst electromag11.png
Whereas the familiar battery symbol is used as a generic symbol for any DC voltage source, the circle with the wavy line inside is the
generic symbol for any AC voltage source.
One might wonder why anyone would bother with such a thing as AC. It is true that in some cases AC holds no practical advantage over DC.
In applications where electricity is used to dissipate energy in the form of heat, the polarity or direction of current is irrelevant, so
long as there is enough voltage and current to the load to produce the desired heat (power dissipation). However, with AC it is possible to
build electric generators, motors and power distribution systems that are far more efficient than DC, and so we find AC used predominately
across the world in high power applications. To explain the details of why this is so, a bit of background knowledge about AC is
necessary.
If a machine is constructed to rotate a magnetic field around a set of stationary wire coils with the turning of a shaft, AC voltage will be
produced across the wire coils as that shaft is rotated, in accordance with Faraday's Law of electromagnetic induction. This is the basic
operating principle of an AC generator, also known as an alternator:
Fhsst electromag12.png
Notice how the polarity of the voltage across the wire coils reverses as the opposite poles of the rotating magnet pass by. Connected to a
load, this reversing voltage polarity will create a reversing current direction in the circuit. The faster the alternator's shaft is
turned, the faster the magnet will spin, resulting in an alternating voltage and current that switches directions more often in a given
amount of time.
While DC generators work on the same general principle of electromagnetic induction, their construction is not as simple as
their AC counterparts. With a DC generator, the coil of wire is mounted in the shaft where the magnet is on the AC alternator, and
electrical connections are made to this spinning coil via stationary carbon "brushes" contacting copper strips on the rotating shaft. All
this is necessary to switch the coil's changing output polarity to the external circuit so the external circuit sees a constant polarity:
Fhsst electromag13.png
The generator shown above will produce two pulses of voltage per revolution of the shaft, both pulses in the same direction (polarity).
In order for a DC generator to produce constant voltage, rather than brief pulses of voltage once every 1/2 revolution, there
are multiple sets of coils making intermittent contact with the brushes. The diagram shown above is a bit more simplified than what
you would see in real life.
The problems involved with making and breaking electrical contact with a moving coil should be obvious (sparking and heat), especially if the
shaft of the generator is revolving at high speed. If the atmosphere surrounding the machine contains flammable or explosive vapors, the
practical problems of spark-producing brush contacts are even greater. An AC generator (alternator) does not require brushes and commutators
to work, and so is immune to these problems experienced by DC generators.
The benefits of AC over DC with regard to generator design is also reflected in electric motors. While DC motors require the use of
brushes to make electrical contact with moving coils of wire, AC motors do not. In fact, AC and DC motor designs are very similar to
their generator counterparts (identical for the sake of this tutorial), the AC motor being dependent upon the reversing magnetic
field produced by alternating current through its stationary coils of wire to rotate the rotating magnet around on its shaft, and the DC
motor being dependent on the brush contacts making and breaking connections to reverse current through the rotating coil every 1/2
rotation (180 degrees).
So we know that AC generators and AC motors tend to be simpler than DC generators and DC motors. This relative simplicity translates into
greater reliability and lower cost of manufacture. But what else is AC good for? Surely there must be more to it than design details of
generators and motors! Indeed there is. There is an effect of electromagnetism known as mutual induction, whereby two or
more coils of wire placed so that the changing magnetic field created by one induces a voltage in the other. If we have two mutually
inductive coils and we energize one coil with AC, we will create an AC voltage in the other coil. When used as such, this device is known as
a transformer:
Fhsst electromag14.png
The fundamental significance of a transformer is its ability to step voltage up or down from the powered coil to the unpowered coil. The
AC voltage induced in the unpowered ("secondary") coil is equal to the AC voltage across the powered ("primary") coil multiplied by the ratio
of secondary coil turns to primary coil turns. If the secondary coil is powering a load, the current through the secondary coil is just the
opposite: primary coil current multiplied by the ratio of primary to secondary turns. This relationship has a very close mechanical
analogy, using torque and speed to represent voltage and current, respectively:
Fhsst electromag15.png
If the winding ratio is reversed so that the primary coil has less turns than the secondary coil, the transformer "steps up" the voltage
from the source level to a higher level at the load:
Fhsst electromag16.png
The transformer's ability to step AC voltage up or down with ease gives AC an advantage unmatched by DC in the realm of power
distribution. When transmitting electrical power over long distances, it is far more efficient to do so with stepped-up voltages and
stepped-down currents (smaller-diameter wire with less resistive power losses), then step the voltage back down and the current back up for
industry, business, or consumer use use.
Fhsst electromag17.png
Transformer technology has made long-range electric power distribution practical. Without the ability to efficiently step voltage up and
down, it would be cost-prohibitive to construct power systems for anything but close-range (within a few miles at most) use.
As useful as transformers are, they only work with AC, not DC. Because the phenomenon of mutual inductance relies on
changing magnetic fields, and direct current (DC) can only produce steady magnetic fields, transformers simply will not work with
direct current. Of course, direct current may be interrupted (pulsed) through the primary winding of a transformer to create a changing
magnetic field (as is done in automotive ignition systems to produce high-voltage spark plug power from a low-voltage DC battery), but
pulsed DC is not that different from AC. Perhaps more than any other reason, this is why AC finds such widespread application in power
systems.
If we were to follow the changing voltage produced by a coil in an alternator from any point on the sine wave graph to that point when
the wave shape begins to repeat itself, we would have marked exactly one cycle of that wave. This is most easily shown by
spanning the distance between identical peaks, but may be measured between any corresponding points on the graph. The degree marks on
the horizontal axis of the graph represent the domain of the trigonometric sine function, and also the angular position of our
simple two-pole alternator shaft as it rotates:
Fhsst electromag18.png
Since the horizontal axis of this graph can mark the passage of time as well as shaft position in degrees, the dimension marked for one
cycle is often measured in a unit of time, most often seconds or fractions of a second. When expressed as a measurement, this is often
called the period of a wave. The period of a wave in degrees is always 360, but the amount of time one period occupies
depends on the rate voltage oscillates back and forth.
A more popular measure for describing the alternating rate of an AC voltage or current wave than period is the rate of that
back-and-forth oscillation. This is called frequency. The modern unit for frequency is the hertz (abbreviated Hz), which
represents the number of wave cycles completed during one second of time. In the United States of America, the standard power-line
frequency is 60 Hz, meaning that the AC voltage oscillates at a rate of 60 complete back-and-forth cycles every second. In Europe, where
the power system frequency is 50 Hz, the AC voltage only completes 50 cycles every second. A radio station transmitter broadcasting at a
frequency of 100 MHz generates an AC voltage oscillating at a rate of 100 million cycles every second.
Period and frequency are mathematical reciprocals of one another. That is to say, if a wave has a period of 10 seconds, its frequency
will be 0.1 Hz, or 1/10 of a cycle per second:
An instrument called an oscilloscope is used to display a changing voltage over time on a graphical screen. You may be familiar
with the appearance of an ECG or EKG (electrocardiograph) machine, used by physicians to graph the
oscillations of a patient's heart over time. The ECG is a special-purpose oscilloscope expressly designed for medical use.
General-purpose oscilloscopes have the ability to display voltage from virtually any voltage source, plotted as a graph with time as the
independent variable. The relationship between period and frequency is very useful to know when displaying an AC voltage or current
waveform on an oscilloscope screen. By measuring the period of the wave (in seconds) on the horizontal axis of the oscilloscope screen and
reciprocating that time value, you can determine the frequency in hertz.
Fhsst electromag19.png
Voltage and current are by no means the only physical variables subject to variation over time. Much more common to our everyday
experience is sound, which is nothing more than the alternating compression and decompression (pressure waves) of air
molecules, interpreted by our ears as a physical sensation. Because alternating current is a wave phenomenon, it shares many of the
properties of other wave phenomena, like sound. For this reason, sound (especially structured music) provides an excellent analogy for
relating AC concepts.
In musical terms, frequency is equivalent to pitch. Low-pitch notes such as those produced by a tuba or bassoon consist of
air molecule vibrations that are relatively slow (low frequency). High-pitch notes such as those produced by a flute or whistle consist
of the same type of vibrations in the air, only vibrating at a much faster rate (higher frequency). Here is a table showing the actual
frequencies for a range of common musical notes:
Fhsst electromag20.png
Astute observers will notice that all notes on the table bearing the same letter designation are related by a frequency ratio of 2:1. For
example, the first frequency shown (designated with the letter "A") is 220 Hz. The next highest "A" note has a frequency of 440 Hz -
exactly twice as many sound wave cycles per second. The same 2:1 ratio holds true for the first A sharp (233.08 Hz) and the next A
sharp (466.16 Hz), and for all note pairs found in the table.
Audibly, two notes whose frequencies are exactly double each other sound remarkably similar. This similarity in sound is musically
recognized, the shortest span on a musical scale separating such note pairs being called an octave. Following this rule, the next
highest "A" note (one octave above 440 Hz) will be 880 Hz, the next lowest "A" (one octave below 220 Hz) will be 110 Hz. A view of a
piano keyboard helps to put this scale into perspective:
Fhsst electromag21.png
As you can see, one octave is equal to eight white keys' worth of distance on a piano keyboard. The familiar musical mnemonic
(doe-ray-mee-fah-so-lah-tee-doe) - yes, the same pattern immortalized in the whimsical Rodgers and Hammerstein song sung in The Sound of Music - covers one octave from C to C.
While electromechanical alternators and many other physical phenomena naturally produce sine waves, this is not the only kind of alternating
wave in existence. Other "waveforms" of AC are commonly produced within electronic circuitry. Here are but a few sample waveforms and
their common designations:
Fhsst electromag22.png
These waveforms are by no means the only kinds of waveforms in existence. They're simply a few that are common enough to have been
given distinct names. Even in circuits that are supposed to manifest "pure" sine, square, triangle, or sawtooth voltage/current waveforms,
the real-life result is often a distorted version of the intended waveshape. Some waveforms are so complex that they defy
classification as a particular "type" (including waveforms associated with many kinds of musical instruments). Generally speaking, any
waveshape bearing close resemblance to a perfect sine wave is termed sinusoidal, anything different being labeled as
non-sinusoidal. Being that the waveform of an AC voltage or current is crucial to its impact in a circuit, we need to be aware of
the fact that AC waves come in a variety of shapes.