Stereotactic Radiosurgery (SRS)
Clinical Sites
Overview
CNS Page
Malignant
Brain Metastases
Pineal Gland tumors
Benign:
Meningioma
Acoustic Neuroma (Vestibular Schwannoma)
Pituitary Adenoma
Trigeminal Neuralgia
Sphenopalatine Neuralgia
Chronic Cluster Headaches
Arteriovenous Malformation (AVM)
Cavernous Malformation
Glomus Jugulare (Paraganglioma)
Epilepsy
Cancer pain
Treatment planning indices
Thieme; 2018 (29699833): Voxel-Based Homogeneity Index (VHI)
VHI = k ∫ ∫ ∫ (D(x,y,z)/PD - 1)² / TV
D(x,y,z) = Dose at coordinates (x,y,z)
PD = prescribed dose
TV = Target volume size
k = 10^4
Sensitive homogeneity index which uses voxel information for score calculation
Yomo; 2010 (19809786): Energy Index
EI = ID / (TV x PD)
ID = integral dose within target volume
PD = prescribed dose
Measure of dose homogeneity within target volume
Oliver; 2007 (17194494): Radical Dose Homogeneity Index
rDHI = Dmin / Dmax
Dmin = minimum dose within target volume
Dmax = maximum dose within target volume
Oliver; 2007 (17194494): Moderate Dose Homogeneity Index
mDHI = D95% / D5%
D95% = dose to 95% of target volume
D5% = dose to 5% of target volume
Paddick; 2006 (18503356): Dose Gradient Index
GI = PIVhalf / PIV
PIVhalf = Prescription isodose volume, at half the prescription isodose (e.g. at 25%)
PIV = Prescription isodose volume (e.g. at 50%)
Simplified UF Gradient Index
Wagner; 2003 (14575847): Conformity Gradient Index
CGI = (CGIc + CGIg) / 2
CGIc = TV / PIV * 100
CGIg = UF Gradient Index (see below)
Wagner; 2003 (14575847): UF Gradient Index
CGIg = 100 - (100 * ((REff,50%Rx - REff,Rx) - 0.3 cm))
REff,50%Rx = Effective radius of the isodose line that is equal to one-half of the prescription isodose volume
REff,Rx = Effective radius of the prescription volume
Evaluates the steepness of the gradient between prescription isodose line (e.g 50%) and half prescription isodose line (e.g. 25%)
Nakamura; 2001 (11728692): New Conformity Index
NCI = (TV x PIV) / (TVPIV)2
Inverse Paddick Conformity Index
Paddick; 2000 (11143252): Paddick Conformity Index
Paddick CI = (TVPIV)2 / (TV x PIV)
TVPIV = Target Volume covered by Prescription Isodose Volume
TV = Target Volume
PIV = Prescription Isodose Volume
This is two separate ratios multiplied together:
Undertreatment ratio: TVPIV / TV
Overtreatment ratio: TVPIV / PIV
ICRU; 1999 (ICRU Report): Conformity Index
CI = TV / PTV
TV: Treated volume = volume eclosed by a given isodose surface (e.g. 50%, 95%)
PTV: Planning target volume = CTV + IM + SM
RTOG conformity index with ICRU terminology
Knoos; 1998 (9869245): Radiation Conformity Index
RCIi = PTV / PIV
PTV: Planning target volume = CTV + IM + SM
PIV = Prescription Isodose Volume
Inverse of RTOG Conformity Index
RTOG; 1993 (8262852): Conformity Index
Conformity Index PITV = PIV / TV
PI = prescription isodose volume
TV = target volume
Normal 1.0-2.0, minor deviation if >2.0 or <1.0, major deviation if >2.5 or <0.9
RTOG; 1993 (8262852): Homogeneity
Homogeneity MDPD = MD / PD
MD = maximum dose within target volume
PD = prescribed dose
Minor deviation if >2.0, major deviation if >2.5
RTOG; 1993 (8262852): Coverage
Coverage = Dmin / PD
Dmin = minimum dose within target volume
PD = prescribed dose
Minor deviation if <0.9, major deviation if <0.8
Wu; 1988 (3352544): Dose Homogeneity Index
DHI: (VTDR - VHDR) / VTDR
VTDR = total treatment volume enclosed by prescribed treatment dose rate (PIV)
VHDR = volume enclosed by high-dose rate which is 1.5x TDR or greater (PIV1.5x)
Used for high dose rate brachytherapy implants, but applicable to SRS
Other literature
Lomax; 2003 (12654454)
van't Riet; 1997 (9112473)
Dose overview
Doses are prescribed to the 50% isodose line unless stated otherwise
Brain metastases: 24 Gy, 18 Gy, 15 Gy for tumors <2 cm, 2.1-3cm, and 3.1-4 cm.
Trigeminal neuralgia: 40 Gy (80 Gy Dmax), using 4mm collimator
Acoustic neuroma (vestibular schwannoma): 12.5 Gy
Meningioma: 12-14 Gy
Arteriovenous malformation: 18-20 Gy
Gamma Knife Machines
Hopital Timone, Marseille (2006) -- GKS 4C vs PerfeXion
Randomized. 200 patients. Arm 1) GammaKnife 4C vs Arm 2) GammaKnife PerfeXion
2009 19190462 -- "Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: a 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C." (Regis J, Neurosurgery. 2009 Feb;64(2):346-55; discussion 355-6.)
Outcome: No technical failures. Median # of collimator sizes 4C 1 vs PerfeXion 2. Median treatment time 60 min vs 40 min (SS), but median beam-on time 33.4 vs 34.0 minutes (NS). Single run 42% vs. 99%. Collision risk requiring gamma angle 24% vs 0%.
Toxicity: Less dose with PerfeXion to vertex (8x), thyroid (10x), sternum (13x), and gonads (15X)
Conclusion: Technological advances with PerfeXion
CyberKnife System
The CyberKnife System is a radiation therapy device manufactured by Accuray Incorporated
The system is used to deliver radiosurgery for the treatment of benign tumors, malignant tumors and other medical conditions
Charged-Particle Radiosurgery
Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for almost 60 years
Energetic beams of charged particles of proton mass or greater (e.g., nuclei of hydrogen, helium or carbon atoms) manifest unique physical and radiobiological properties that offer advantages for neurosurgical application and for neuroscience research
These beams can be readily collimated to any desired cross-sectional size and shape
At higher kinetic energies, the beams can penetrate entirely through the patient in a similar fashion to high-energy photon beams but without exponential fall-off of dose
At lower kinetic energies, the beams exhibit increased dose-deposition (Bragg ionization peak) at a finite depth in tissue that is determined by the beam’s energy as it enters the patient
These properties enable highly precise, 3-dimensional placement of radiation doses to conform to uniquely shaped target volumes anywhere within the brain
Toxicity
Please see the toxicity page for further information