411 REFERENCE · Wikibooks
HydroGeoSphere/Variably-Saturated Flow
Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.
By default, HydroGeoSphere uses the upstream weighting scheme (weighted harmonic mean) for relative permeability, with an upstream weighting factor value of 1.0. The default behaviour can be changed using the following commands:
Upstream weighting factor
upwfactor Upstream weighting factor.
Assigns a new value for the upstream weighting factor, which defaults to 1.0. This value should be in the range from 0.5 (central weighting) to 1.0 (upstream weighting).
• • •
Central weighting
Causes HydroGeoSphere to use central weighting (weighted arithmetic mean) instead of upstream weighting.
• • •
Primary variable switching
Causes HydroGeoSphere to use the primary variable substitution technique outlined in Section 3.13.3.
• • •
If desired, the default values of and , the upper and lower limits for variable substitution (see Equation 3.99) can be changed using the following commands:
Upper limit
switch_t Upper limit of the variable substitution approach, tolf in Equation 3.99. The default value is 0.99.
• • •
Lower limit
switch_f Lower limit of the variable substitution approach, tolb in Equation 3.99. The default value is 0.89.
• • •