411 REFERENCE · Wikibooks
HydroGeoSphere/Pore Water Freezing and Thawing
Reference material by Wikibooks contributors. This retains its source identity and is not 411 news reporting.
To calculate the freezing and thawing of pore water, HydroGeoSphere requires the following set of instructions:
Pore water freezing-thawing...End
grok reads instructions that define the pore water freezing and thawing parameters for the domain until it encounters an End instruction.
• • •
For example:
pore water freezing-thawing
surface temperature
0 -7.0
2592000 -6.1
5184000 -0.9
7776000 6.2
10368000 12.9
12960000 18.0
15552000 20.2
18144000 19.3
20736000 14.8
23328000 8.6
25920000 2.4
28512000 -4.0
31104000 -7.0
end
thermal diffusivity
0.2d-6
background temperature
6.0d0
melting temperature
0.5d0
freezing temperature
-0.5d0
maximum freezing depth
2.0d0
integration convergence criteria
1.0e-4
memory length for convolution integral
15552000.0d0 ! 6*30*86400 sec = 6 months
end
Surface temperature
time(i), val(i)...end The time and surface temperature value list.
At time time(i) the value val(i) is applied and maintained until time time(i+1). The last value entered in the list will be applied until the end of the simulation.
• • •
Thermal diffusivity
val Thermal diffusivity [L2 T−1].
• • •
Background temperature
val Background temperature [Θ].
• • •
Melting temperature
val Melting temperature [Θ].
• • •
Freezing temperature
val Freezing temperature [Θ].
• • •
Maximum freezing depth
val Maximum freezing depth [L].
• • •
Integration convergence criteria
val Integration convergence criteria.
• • •
Memory length for convolution integral
val Memory length for convolution integral.
• • •