1954 Bitburg explosion

Reference material by Wikipedia contributors. This retains its source identity and is not 411 news reporting.

Industrial disaster in Germany The devastating Bitburg tank explosion took place on 23 September 1954 at the then NATO air base near the city Bitburg, in the municipality of Niederstedem, Germany. The explosion took place in an underground storage tank containing JP-4, a military jet fuel blend. The toll was 34 dead, 2 injured, 3 missing.Ritter W.G. Underground JP-4 fuel tank explosion: Bitburg Germany, 34 dead, 2 injured and 3 missing, September 23, 1954 NFPA Fire Loss Bull 1955 1 1–4 The explosion was caused by the deliberate activation of a novel carbon dioxide fire extinguishment system during an acceptance test as part of final commissioning. The JP-4 blend has since largely been abandoned due to safety concerns because of its low flash point. The accident In 1954 at the US Air Force fuel depot near Bitburg, various acceptance tests were being made on a newly constructed underground fuel storage tank. The tank was fitted with a novel carbon dioxide fire extinguishing system, the first of its kind in Germany. The US Army was not responsible for design, construction and operation of storage facilities at the time, but the fuel involved was the property of the United States. The senior engineering staff of the French La mission des grands travaux aéronautiques en Allemagne and other French and German officials, technicians and contractors were present at the site and attending an acceptance test. The diameter of the underground tank was about 96 feet (29 m) with a total capacity of 1,386,000 US gal (5,250 m3). The tank was about 20% full at the time of the accident. The roof of the underground tank was capped with iron reinforced concrete and covered with a layer of soil. The CO2 cylinders were located in a half-buried concrete structure about 250 feet (75 m) from the storage site. 120 gas cylinders, each with a liquid gas capacity of 30 kg, were connected together in a three battery arrangement. A buried steel pipeline connected the battery with the storage tank. Most if not all of the victims were standing on the top of the tank during a controlled activation of the thermal sensing devices that would trigger CO2 cylinders to discharge gas into the tank's headspace. At about 16:00 hours, one minute after the CO2 discharge commenced, a massive explosion disintegrated the tank. Although the ability of liquefied CO2 to create static electricity upon depressurization was reported as early as in 1925, it was unknown to the tank designers and not identified in the official investigation of the accident by the US Army. It was only identified later in a report Nabert K Schön G Folgerungen aus den Untersuchungen über die Ursache der Explosionskatastrophe bei Bitburg Erdöl und Kohle 1955 8 809–810 by German scientists. Relevance The accident has relevance today as it demonstrates the dangers of static electricity when injecting carbon dioxide into an ignitable atmosphere. As such, it is a case example of de-learning. Knowledge on hazards learned the hard way through accidents can be forgotten. This has happened in the fast-growing wood pellet industry where trouble with smoldering fires in storage silos has led to new techniques for firefighting which employ injection of inert gases such as carbon dioxide. Hedlund FH Carbon dioxide not suitable for extinguishment of smouldering silo fires: static electricity may cause silo explosion Biomass and Bioenergy 108 113–119 Elsevier 2018 10.1016/j.biombioe.2017.11.009 Although the electrostatic hazard has been known for more than 50 years, many standards, guidelines, recent editions of frequently cited pellet handbooks, and other literature cover the hazard superficially or do not mention it at all. The hazard is insufficiently covered in NFPA 12 and it may constitute a hazard for seagoing general cargo vessels where fire protection for cargo holds employs pressurized storage of liquefied carbon dioxide.Hedlund, F. H., & Jarleivson Hilduberg, Ø. (2018). Dangers of releasing CO2 to fight fires in the cargo hold of seagoing bulk carriers . Abstract from 8th International Symposium on Energy, Aberdeen, United Kingdom See also Inerting (gas) References 49.932 6.497 type:event_globe:earth_region:DE title Category:1954 disasters in Germany Category:Bitburg-Prüm Category:1954 explosions Category:20th century in Rhineland-Palatinate Category:Military history of Rhineland-Palatinate Category:1954 in military history Category:History of NATO Category:Cold War military history of Germany Category:1954 in West Germany Category:1950s industrial disasters Category:Industrial fires and explosions in Europe Category:Explosions in Germany Category:September 1954 in Europe